| IEC elektrisk | 150 | 275 | 320 | 385 | 440 | ||
| Nominel AC-spænding (50/60 Hz) | 120V | 230V | 230V | 230V | 400V | ||
| Maksimal kontinuerlig driftsspænding (AC) | (LN) | Uc | 150V | 275V | 320V | 385V | 440V |
| (N-PE) | Uc | 255V | |||||
| Nominel afgangsstrøm (8/20μs) | (LN)/(N-PE) | In | 20kV/20kA | ||||
| Maksimal afgangsstrøm (8/20μs) | (LN)/(N-PE) | Imax | 40kA/40kA | ||||
| Spændingsbeskyttelsesniveau | (LN)/(N-PE) | Up | 1,0kV/1,5kV | 1,5kV/1,5kV | 1,6kV/1,5kV | 1,8kV/1,5kV | 2,0kV/1,5kV |
| Følg den aktuelle afbrydelsesvurdering | (N-PE) | Hvis jeg | 100 ARME | ||||
| Responstid | (LN)/(N-PE) | tA | <25ns/<100ns | ||||
| Reservesikring (maks.) | 125A gL/gG | ||||||
| Short-Cuit Current Rating (AC) | (LN) | ISCCR | 20kA / 50kA | ||||
| TOV Tåler 5s | (LN) | UT | 180V | 335V | 335V | 335V | 580V |
| TOV 120 min | (LN) | UT | 230V | 440V | 440V | 440V | 765V |
| mode | Modstå | Sikker fejl | Sikker fejl | Sikker fejl | Sikker fejl | ||
| TOV Tåler 200ms | (N-PE) | UT | 1200V | ||||
| Driftstemperaturområde | -40ºF til +158ºF[-40ºC til +70ºC] | ||||||
| Tilladt driftsfugtighed | Ta | 5 %…95 % | |||||
| Atmosfærisk tryk og højde | RH | 80k Pa..106k Pa/-500m..2000m | |||||
| Terminalskruemoment | Mmax | 39,9 lbf-in[4,5 Nm] | |||||
| Ledertværsnit (maks.) | 2 AWG (solid, strandet) / 4 AWG (fleksibel) | ||||||
| 35 mm2 (Solid, Strandet) / 25 mm2 (Fleksibel) | |||||||
| Montering | 35 mm DIN-skinne, EN 60715 | ||||||
| Beskyttelsesgrad | IP 20 (indbygget) | ||||||
| Materiale til hus | Termoplast: Slukningsgrad UL 94 V-0 | ||||||
| Termisk beskyttelse | Ja | ||||||
| Driftstilstand / fejlindikation | Grøn ok / Rød defekt | ||||||
| Fjernkontakter (RC) / RC-omskifterkapacitet | Valgfri | ||||||
| RC-ledertværsnit (maks.) | AC:250V/0,5A;DC:250V/0,1A;125V/0,2A;75V/0,5A | ||||||
| 16 AWG (fast) / 1,5 mm2 (fast) | |||||||